This allowed me to achieve an almost perfect 6500k whitepoint. For example, mine is set to R95 G85 and B65. If you cant get all three to the middle, it helps to put all three to 80 (from the default 100) and work from there. This is EXTREMELY important to get as perfect as possible to avoid color banding post calibration. This means you will use your monitors OSD (on screen display) to manually set the R, G, and B values to get you as close to a 6500k whitepoint as possible. The goal is to get all three of those bars in the middle using your monitors custom color presets. You will see three bars for Red, Green and Blue. This will start the interactive color display, click start profiling. Now hit Calibrate & profile at the bottom. ![]() Now go to the "Profiling" sub tab and under Profile type select XYZ LUT + matrix. If your gamma was right at 2.2, leave or set the tone curve to gamma 2.2 and everything else at default. Now go to the "Calibration" sub tab, Whitepoint>Color temperature and type in 6500k. Go to the "display and instrument" sub tab, go over to Instrument>mode> and select LCD White LED. Now that you have the basic information, you are ready to calibrate. My AW38 had a perfect gamma of 2.2 but ran close to 9000k whitepoint which is incredibly blue. This will tell you what your whitepoint and gamma are set to on the stock settings. With your Spyder 5 on your monitor, go to Tools>Report>Report on uncalibrated display and let it run its thing. Once you get Displa圜al to recognize your Spyder5, go to Options and enable advanced settings. On the monitors OSD, use the preset mode "custom color" as you will want to change your RGB values later in the calibration to get the desired whitepoint. I would also turn off the local dimming when you calibrate (Variable backlight >off). The Displa圜al website has good instructions on how to get started.Īlways calibrate with HDR turned off. Download Displa圜al ( ) and use that, you will get a much better calibration by far. Continued abuse of our services will cause your IP address to be blocked indefinitely.First off, do not use the software that the Spyder 5 comes with. ![]() Please fill out the CAPTCHA below and then click the button to indicate that you agree to these terms. If you wish to be unblocked, you must agree that you will take immediate steps to rectify this issue. If you do not understand what is causing this behavior, please contact us here. If you promise to stop (by clicking the Agree button below), we'll unblock your connection for now, but we will immediately re-block it if we detect additional bad behavior.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |